Smart-UPS 3000VA LCD RM 2U 120V
SMT3000RM2U Features
					 								StruxureWare Central compatible: Enables centralized management via StruxureWare Central.
				
					 								Predicitive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.
				
					 								Sine wave output: Eliminates humming and heat generated when powering tubelights and fans.
				
					 								LED Indicators: Provide easy-to-read status of the unit and utility power conditions.
				
					 								Boost and Trim Automatic Voltage Regulation (AVR): Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
				
					 								Serial connectivity: Use any Home Automation network  to monitor and control the S20 through its RS-232 serial port. For  information on how to communicate with the S20, see APC's Application  Note #102. Crestron and AMX installers should visit their respective  websites for information on how to integrate the S20 into those  networks.
				
					 								Green mode: Patent-pending operating mode  that bypasses unused electrical components in good power conditions to  achieve very high operating efficiency without sacrificing any  protection.
				
					 								Energy meter: Provides actual kilowatt hours of usage for energy conscious users.
				
					 								Predictive replace battery date: Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
				
					 								Intuitive LCD interface: Provides clear and accurate  information in multiple languages with the ability to configure the UPS  locally with easy to use navigation keys.
				
					 								Single switched outlet group: Single outlet group that may be  controlled separately from the UPS for discrete reboot of hung devices,  sequenced on/off and non-critical load shedding.
				
					 								Pure sine wave output on battery: Simulates utility power to  provide the highest degree of compatibility for active PFC (power factor  corrected) servers and sensitive electronics.
				
					 								Disconnected battery notification: Warns when a battery is not available to provide backup power.
				
					 								Sequenced network shutdown and reboot: Customize network shutdown and reboot sequence of connected servers and UPSs.
				
					 								Outlet group control: Turn on/off, reboot or shut down  select outlet groups to save dispatching technicians to remote locations  (for UPSs with switched outlet groups).
				
					 								Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
				
					 								Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
				
					 								Audible alarms: Provides notification of changing utility power and UPS power conditions
				
					 								Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
				
					 								Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
				
					 								Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
				
					 								Network manageable: Provides remote power management of the UPS over the network.
				
					 								Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
				
					 								Safety-agency approved: Ensures the product has been  tested and approved to work safely with the connected service provider  equipment and within the specified environment.
				
					 								Serial connectivity: Provides management of the UPS via a serial port.
				
					 								Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
				
					 								USB connectivity: Provides management of the UPS via a USB port (not available on all models).
				
					 								User-replaceable batteries: Increases availability by  allowing a trained user to perform upgrades and replacements of the  batteries reducing Mean Time to Repair (MTTR)
				
					 								Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application  availability by correcting low and high voltage conditions without using  the battery (not available on all models).
				
					 								Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
					
						
							
					
						
							
								
									
							
								
									
							
								
									
							
								
									
							
								
									
							
								
									
							
								
									
							
								
									
										
										
										
					
						
							
					
						
							
								
									
							
								
									
							
								
									
										
										
										
							
								
									
							
								
									
							
								
									
					
						
							
					
						
							
					
						
							
					
						
							
					
						
							
Output
										 						 							 								 									Output Power Capacity: 2700 Watts	  	 	 	 	  	 		 			 			 			 			/ 2880 VA
									
										 						 							 								 									Max Configurable Power: 2700 Watts	  	 	 	 	  	 		 			 			 			 			/ 2880 VA
									
										 						 							 								 									Nominal Output Voltage: 120V
									
										 						 							 								 									Output Voltage Distortion: Less than 5%
									
										 						 							 								 									Output Frequency (sync to mains): 50/60Hz +/- 3 Hz
									
										 						 							 								 									Topology: Line Interactive
									
										 						 							 								 									Waveform Type: Sine wave
									
										 						 							 								 									Output Connections:
									
									| (6) NEMA 5-15R |   | 
| (2) NEMA 5-20R |   | 
Input
										 						 							 								 									Nominal Input Voltage: 120V
									
										 						 							 								 									Input Frequency: 50/60 Hz +/- 3 Hz (auto sensing)
									
										 						 							 								 									Input Connections:
									
									| NEMA L5-30P |   | 
										 						 							 								 									Cord Length: 2.44 meters
									
										 						 							 								 									Input voltage range for main operations: 82 - 144V
									
										 						 							 								 									Input voltage adjustable range for mains operation: 75 - 154V
									
Batteries & Runtime
								 						 							 								 									Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
							
								 						 							 								 									Typical recharge time: 3 hour(s)
							
								 						 							 								 									Replacement Battery: RBC43
							
								 						 							 								 									RBC™ Quantity: 1
								
									
										
								
									
										
											
												
										
											
												
										
											
												
										
											
												
								
									
										
								
Communications & Management
													 						 							 								 									Interface Port(s): USB
												
													 						 							 								 									Available SmartSlot™ Interface Quantity: 1
												
													 						 							 								 									Control panel: LED status display with On Line : On Battery : Replace Battery and  Overload indicators, Multi-function LCD status and control console
												
													 						 							 								 									Audible Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
												
Surge Protection and Filtering
									 						 							 								 									Surge energy rating : 459 Joules
								